YG-JTDL13 Tunnel COVI Detector
YG-JTDL13 Tunnel COVI Detector
Payment:
T/T, L/C or Paypal
OEM/ODM:
Available
MOQ:
1PCS
Model:
YG-JTDL13
Lead Time:
5-7 days
PRODUCT DESCRIPTION
Tunnels are enclosed, tubular structures with limited space and restricted ventilation. Exhaust emissions from vehicles traveling through tunnels, if not effectively discharged, can lead to the accumulation of carbon monoxide (CO) and suspended particulate matter, posing serious risks to drivers, passengers, and maintenance personnel.
To ensure safety, continuous monitoring of visibility (VI) and carbon monoxide (CO) concentration inside tunnels is essential. This enables timely activation of ventilation systems, such as jet fans, and the implementation of other control measures.
The YG-JTDL13 Tunnel COVI Detector provides 24/7 real-time monitoring of tunnel environmental conditions, making it an indispensable device in modern intelligent transportation systems for enhancing tunnel safety and operational efficiency.

Purpose-Built for Tunnel Applications
High-Precision Optical Measurement
Flexible Power Supply Options
Automatic Compensation Function
Multiple Output Interfaces
Easy Installation & Commissioning
SPECIFICATIONS
| Visibility (VI) | Carbon Monoxide (CO) | |
|---|---|---|---|
Measurement Unit | 1/m | ppm | |
Measurement Method | Optical Transmission Method | Optical Transmission Method | |
Optical Path Length | 6 m (installation distance: 3 m) | 6 m (installation distance: 3 m) | |
Measurement Range | (0 ~ 35 × 10⁻³) 1/m | 0 ~ 400 ppm | |
Accuracy | ±0.0001 1/m | ±1 ppm | |
Operating Temperature | -40°C ~ +75°C | -40°C ~ +75°C | |
Operating Humidity | 0 ~ 100% RH | 0 ~ 100% RH | |
Output Interface | RS485 / 4–20 mA | RS485 / 4–20 mA | |
Output Interval | 60 s | 60 s | |
Data Update Rate | 1 record/min | 1 record/min | |
Light Source Wavelength | 940 nm | 940 nm | |
Power Supply | AC 220V / DC 12V | AC 220V / DC 12V | |
Power Consumption | ≤ 10 W | ≤ 10 W | |
Operating Life | MTBF ≥ 15,000 hours | MTBF ≥ 15,000 hours |