KQZL-1 Ambient Air Quality Monitoring System

Product photo

KQZL-1 Ambient Air Quality Monitoring System

Payment:

T/T, L/C or Paypal

OEM/ODM:

Available

MOQ:

1PCS

Model:

KQZL-1

Lead Time:

5-7 days

PRODUCT DESCRIPTION

The KQZL-1 Micro Environmental Air Quality Monitoring System features a PP alloy enclosure that provides wind resistance, rain protection, lightning protection, and effective heat dissipation and thermal insulation. Custom silk-screen printing is available, offering a clean and professional appearance. The system is suitable for applications in industrial parks, road and traffic environments, residential areas, and commercial districts.

The unit is primarily designed for pole-mounted installation, with an option for wall mounting, making it convenient for outdoor deployment in various environments. The enclosure adopts an explosion-proof overall design, while the internal structure is modular. During maintenance or servicing, individual modules can be replaced as needed.

As the sensor modules are the components with relatively shorter service life in the system and require periodic replacement depending on sensor type, a detachable modular design is adopted. This allows trained on-site personnel to easily replace the sensors, improving maintenance efficiency and reducing downtime.

Image
Image
High Accuracy & Stability
Image
Intelligent & Modular Design
Image
Strong Anti-Interference Performance
Image
Comprehensive Alarms & Remote Management
Image
Flexible Deployment & Power Options
Image
Low Maintenance & Easy Operation

SPECIFICATIONS

Monitoring Parameters

SO₂, NO₂, CO, O₃, PM2.5, PM10, TVOC, Temperature, Humidity, Wind Direction, Wind Speed, Atmospheric Pressure (Expandable)

Sensor Service Life

2 years

Operating Temperature

-30 ~ +50 °C

Operating Humidity

0 ~ 95% RH

Operating Pressure

80 ~ 120 kPa

Operating Voltage

AC 220V / DC 12V

Power Consumption

< 1.2 W

Communication Interfaces

RS485 / RS232 / Wireless GPRS

Communication Mode

Request – Response

Data Update Interval

10 s; data after 48 hours of operation is recommended as stable reference data

Warm-up Time

≥ 6 h; first-time use requires extended power-on: ≥ 24 h

Cross-Interference Handling

Atmospheric module + core control board; optional built-in cross-interference compensation algorithm

Applicable Standards

GB 4208-2008, GB/T 15479-1995, HJ 653-2013, JJF 1172-2007, JJG 968-2002

Sensor Technical Specifications

Parameter

Measurement Range

Resolution

Accuracy

Ambient Temperature

-40 ~ +80 °C

0.1 °C

±0.2 °C

Ambient Humidity

0 ~ 100% RH

0.1% RH

±2% RH (≤80% RH)

±5% RH (>80% RH)

Ultrasonic Wind Direction

0 ~ 360°

1°

±3°

Ultrasonic Wind Speed

0 ~ 75 m/s

0.1 m/s

±(0.3 + 0.03V) m/s

Atmospheric Pressure

300 ~ 1100 hPa

0.1 hPa

±0.3 hPa

Ozone (O₃)

0 ~ 500 ppb

1 ppb

±10% FS

Carbon Monoxide (CO)

0 ~ 4000 ppb

1 ppb

±10% FS

Sulfur Dioxide (SO₂)

0 ~ 500 ppb

1 ppb

±10% FS

Nitrogen Dioxide (NO₂)

0 ~ 500 ppb

1 ppb

±10% FS

PM2.5

0 ~ 1000 µg/m³

1 µg/m³

±10%

PM10

0 ~ 1000 µg/m³

1 µg/m³

±10%

TVOC

0 ~ 20 ppm

1 ppb

±10% FS